Basic Code Execution

Time Dependent Calculations

Calculations in sedona can be run either as time evolving or steady-state models. This is controlled by time-stepping parameters

Time Stepping Parameters
parameter values definition
tstep_max_steps <integer> Maximum number of time steps to take before exiting
tstep_time_start <real> Start time (in seconds)
tstep_time_stop <real> Stop time (in seconds)
tstep_max_dt <real> Maximum value of a time step (in seconds)
tstep_min_dt <real> Minimum value of a time step (in seconds)
tstep_max_delta <real> Maximum fractional size of a timestep, restricts dt to the specified value multiplied by the current time

Times are always in seconds.

Steady State Calculations